If you just want to take advantage of all the features of our panel remember our panel works with just about every sensor on the market today. 24v to 12v Convertors available 
The is the start up screen for the version 2.0. When you push the up or down arrow you will get the screen below. New Legacy 6.0 & 7.0 Version 2.0 Same size as regular Legacy panels but has new firmware Default Screen above. When you want to detail your tanks just push the up or down arrow to see the screen below. 
Version 2.0 is available in Larger Profile Panel and Legacy 6.0 & 7.0 sizes We can upgrade your Profile or Legacy Panels Call for Details 
1-8 tank Profile Water, Waste, Gasoline & Diesel PANEL ONLY Panel size 6.5" H X 5.0" W Cut out size 5 3/4" H X 4 1/4" W 
The is the start up screen for the Legacy panel. 1-8 tank Profile Series, Legacy Model Water, Waste, Gasoline & Diesel PANEL ONLY Two sizes to choose from Panel Size 6.0" W X 3.8" H Panel Size 7.0" W X 3.8" H Cut out size 5 1/8" W X 3 1/8" H Custom panel sizes available 
1 Tank Solo Panel with one sensor kit
Panel size 2.0" H X 3.5" W Cut out size 1.5" H X 2.5/8" W

1 Tank Solo Panel for Waste tank with Full alert and one sensor kit
Panel size 2.0" H X 3.5" W Cut out size 1.5" H X 2.5/8" W 
1 Tank Solo Panel for Fresh Water tank with Empty Alert and one sensor kit
Panel size 2.0" H X 3.5" W Cut out size 1.5" H X 2.5/8" W  
Profile Solo Display Module For Under-Counter InstallationExterior Sensor Kit Included This version of our popular Solo tank monitor and display is functionally identical to the Solo display panels described above, it is just housed in a sturdy ABS enclosure for easy under-counter or under-cabinet installation.
Of all our tank monitors and displays, this is by far the easiest to install as there is no panel cutout to make. To secure it you just need 4 screws.
Additionally, the Empty and Full calibration buttons have been hidden away inside of this units housing thereby preventing inadvertent re-calibration or re-configuration by children or curious guests.
Basic Features:- Runs our simplified EZ-Profile algorithm.
- Monitors one tank.
- Tank level displayed in quarters.
- Optional autonomous tank monitoring.
- Optional tank high/low alert light.
- Compatible with all of our capacitive sensors, most capacitive sensors manufactured by other companies, & 240-33 Ohm float sensors.
- Push button empty/full calibration.
- Overall module dimensions: 4 5/16" wide (measured at the flange) by 1 5/8" tall by 2 1/2" deep
- Visible face dimensions: 3 1/8" wide by 1 5/8" tall.
 
PVC Rod for Metal Tanks. View of 1" pipe thread fitting. Bottom end is sealed or can be shipped open ended and you cut and seal with simple instructions. Reading is through the PVC pipe. This is a non fouling rod in waste tanks. To right 5 Hole SAE to 1" flange for our water & waste rods The flange can be purchased for $19.95 
For customers without access to the top of their tank we also build this sensor with a 90 bend (sensor head pictured above at right) to mount through a hole in the side wall of your tank. This sensor variant is built with one of our SAE-5 to 1" NPT adapters attached and requires the SAE-5 hole sensor mounting pattern be present on your tank. Basic Features:- Monitors fresh water or waste tanks.
- Sensor lengths in excess of 48".
- Installs in a 1" NPT threaded hole in the top of the tank.
- SAE-5 to 1" NPT adapter available for mounting.
- Sensor also available with a 90 bend for mounting through a tank side wall.
- Power-on light for troubleshooting.
- No moving parts to foul.
Call for pricing, varies on exact size in and down
Our new 8 tank monitoring system for Boats & RV's is the most modern panel on the market. It features our new EZ-Profile software that greatly improves the linearity and accuracy of the displayed tank level. We have also designed a state of the art non-contact sensor, which mount on the outside of plastic or fiberglass tanks. This panel is great for the do-it-yourselfer as all panel functions can be quickly setup via a series of easy to follow menus. Electrical connections are also a snap as they are made on a series of screw down terminals located on the back of the panel. OEM customers will also appreciate our OEM setup menu option in which we pre-program a variety of tank configurations that can be selected from at install time. This way our OEM customer can purchase one panel part number for all models they produce instead of many different pre-programmed panels. Key Features: 1. From 1 to 8 fluid tanks can be monitored autonomously 2. Basic cross-sectional shape of each tank can be set to improve the linearity of tank readings 3. Panel is compatible with non-contact sensors as well as 240-33 Ohm float-style sensors 4. 0-90 Ohm LP tank sender output can be displayed 5. 4x20 text LCD display with backlighting 6. New panel is fully user configurable Hardware Features: 1. 4x20 text LCD display with automatic backlighting (back light enabled at night via a light sensor) 2. Red warning light indicates a tank out-of-bounds condition 3. Audible alarm warns of a tank out-of-bounds (audible alarm disabled at night via a light sensor) 4. Rocker switch provided for on/off control 5. Green power-on LED 6. All electrical connections made on screw-down terminal strips on the back of the panel making electrical connections simple to make (and re-make) should a mistake in wiring be made during installation) 7. Overall panel size: 6.5" x 5", 3.8" x 6.0 and other sizes are available in our 1-8 tank. Software Features: 1. Users can fully configure the panel through a series of on-screen menus: a. The number of sensor channels to be monitored (from 1 to 8) b. The name for each monitored sensor channel (i.e.: FORWARD FRESH, PORT WASTE, etc...) c. Type of sensor attached to each sensor channel (non-contact sensors, or 240-33 Ohm float style sensors) d. Alarm-on-empty or alarm-on-full can be set for each channel e. Time interval for autonomous sensor reading f. Basic cross-sectional shape of each tank can be set to improve the linearity of tank readings 2. Panel autonomously monitors each connected sensor channel: a. Red warning light is lit continuously when any channel which is out of bounds (a fresh or fuel tank is too low, or a waste tank is too full) b. Audible alarm sounds when all channels are updated (time interval for update set by user) to alert the user that that something amiss except at night when the audible alarm is suppressed by a light sensor c. "HI," "LO," or "OK" tank status is indicated with the 10 position bar graph on the LCD display DOWNLOAD THE MANUALS YOU NEED NEW PDF** FOR PROFILE & LEGACY 1-8 TANK VERSION 2.0 NEW CLICK ON ABOVE PDF* PROFILE & Legacy 1-8 TANKS* CLICK ON ABOVE
PDF*SOLO OPERATING & INSTRUCTION MANUAL REGULAR & UNDERMOUNT* CLICKON ABOVE SOLO PANEL DRAWING Click on above
PDF*SENSOR INSTALLATION MANUAL* CLICK ON ABOVE
PDF*PVC ROD SENSOR MANUAL* CLICK ON ABOVE
PDF*INSTRUCTIONSFOR CUTTING OPEN ENDED PVC* CLICK ON ABOVE
PDF*HOLE PATTERN FOR BENT ROD FLANGE CLICK ON ABOVE
Below are flyers which show our products
|